Experimental Investigation of Trombe Wall Performance During Cold Winter Conditions
A Case Study of Duhok City
DOI:
https://doi.org/10.65542/djei.v2i4.106Keywords:
Trombe wall, Solar energy, Thermal efficiency, Nusselt numberAbstract
For indoor heating, a Trombe wall is a passive solar heating system that collects and stores solar energy. However, the thermal efficiency of conventional Trombe wall systems is frequently low. In this study, two rooms were constructed using sandwich panel material, each measuring (0.5 x 0.5 x 0.5) m3, in the city of Duhok, Iraq. A Trombe wall was constructed facing south in both rooms. In Model - A, the Trombe wall was constructed using thermostone block, and in Model - B, it was constructed using brick. The results showed that the performance of a Trombe wall made of thermostone was better than that of a Trombe wall made of brick. The results showed that the ventilation energy, convection heat transfer, average Nusselt number and thermal efficiency of thermostone block was higher than that of bricks by a certain percentage 24%, 68%, 10% and 60% respectively.
References
Kandilli, C.; Gür, M.; Yilmaz, H.; Öztop, H.F. An Experimentally Validated Numerical Model for the Parametrical Evaluation of a Full Scale Innovative Trombe Wall of a Nearly Zero Energy Building Based on Composite Natural Zeolite Plates. Energy 2025, 340, 139316, doi:https://doi.org/10.1016/j.energy.2025.139316. DOI: https://doi.org/10.1016/j.energy.2025.139316
2. Karanafti, A.; Badino, E.; Serra, V.; Fantucci, S. Experimental Study on the Effect of the Ventilation and Operation Mode on the Thermal Efficiency of a Full-Scale Trombe Wall under Real Operating Conditions. Sol. Energy 2025, 302, 114039, doi:https://doi.org/10.1016/j.solener.2025.114039. DOI: https://doi.org/10.1016/j.solener.2025.114039
3. Friji, K.; Ghriss, O.; Bouabidi, A.; Cuce, E.; Rashid, F.L.; Ashour, A.M.; Kadhim, S.A. Thermal Performance of Trombe Wall with Fins: Experimental and CFD Analysis. Appl. Therm. Eng. 2025, 279, 127619, doi:https://doi.org/10.1016/j.applthermaleng.2025.127619. DOI: https://doi.org/10.1016/j.applthermaleng.2025.127619
4. Wu, H.; Zhang, G.; Li, J.; Wang, W.; Li, N.; Ji, J.; Yu, B. A Catalytic Trombe Wall with Thermochromic Hydrogel: Experimental and Numerical Study. Appl. Therm. Eng. 2025, 278, 127454, doi:https://doi.org/10.1016/j.applthermaleng.2025.127454. DOI: https://doi.org/10.1016/j.applthermaleng.2025.127454
5. Cao, X.; Wei, W.; Wang, W.; Ji, J.; Yu, B.; Li, N. Energy and Exergy Analysis of a Photocatalytic Trombe Wall Based on Visible-Light Photocatalytic Purification. Renew. Energy 2025, 246, 122942, doi:https://doi.org/10.1016/j.renene.2025.122942. DOI: https://doi.org/10.1016/j.renene.2025.122942
6. Cao, S.; Ling, J.; Wu, T.; Wu, L.; Guo, P. Coupling Vertical Wall-Attached Ventilation with PV-Trombe Wall: A Numerical Simulation Study. J. Build. Eng. 2025, 104, 112342, doi:https://doi.org/10.1016/j.jobe.2025.112342. DOI: https://doi.org/10.1016/j.jobe.2025.112342
7. He, W.; Hong, X.; Wu, X.; Pei, G.; Hu, Z.; Tang, W.; Shen, Z.; Ji, J. Thermal and Hydraulic Analysis on a Novel Trombe Wall with Venetian Blind Structure. Energy Build. 2016, 123, 50–58. DOI: https://doi.org/10.1016/j.enbuild.2016.04.042
8. Corasaniti, S.; Manni, L.; Russo, F.; Gori, F. Numerical Simulation of Modified Trombe-Michel Walls with Exergy and Energy Analysis. Int. Commun. Heat Mass Transf. 2017, 88, 269–276, doi:10.1016/j.icheatmasstransfer.2017.09.005. DOI: https://doi.org/10.1016/j.icheatmasstransfer.2017.09.005
9. Rabani, M.; Kalantar, V.; Rabani, M. Passive Cooling Performance of a Test Room Equipped with Normal and New Designed Trombe Walls: A Numerical Approach. Sustain. Energy Technol. Assessments 2019, 33, 69–82. DOI: https://doi.org/10.1016/j.seta.2019.03.005
10. Hong, X.; Leung, M.K.H.; He, W. Effective Use of Venetian Blind in Trombe Wall for Solar Space Conditioning Control. Appl. Energy 2019, 250, 452–460. DOI: https://doi.org/10.1016/j.apenergy.2019.04.128
11. Wang, D.; Hu, L.; Du, H.; Liu, Y.; Huang, J.; Xu, Y.; Liu, J. Classification, Experimental Assessment, Modeling Methods and Evaluation Metrics of Trombe Walls. Renew. Sustain. Energy Rev. 2020, 124, 109772. DOI: https://doi.org/10.1016/j.rser.2020.109772
12. Saboori, T.; Zhao, L.; Mesgarpour, M.; Wongwises, S.; Mahian, O. A Novel Macro-Scale Machine Learning Prediction Based on High-Fidelity CFD Simulations: A Case Study on the Pore-Scale Porous Trombe Wall with Phase Change Material Capsulation. J. Build. Eng. 2022, 54, 104505. DOI: https://doi.org/10.1016/j.jobe.2022.104505
13. Bevilacqua, P.; Bruno, R.; Szyszka, J.; Cirone, D.; Rollo, A. Summer and Winter Performance of an Innovative Concept of Trombe Wall for Residential Buildings. Energy 2022, 258, 124798. DOI: https://doi.org/10.1016/j.energy.2022.124798
14. Hu, Z.; Zhu, M.; Li, K.; Yang, C.; Wang, Z.; He, W. Thermal Performance of a Novel Water Blind-Trombe Wall System: A Comparative Experimental Investigation. Energy Convers. Manag. 2023, 296, 117677. DOI: https://doi.org/10.1016/j.enconman.2023.117677
15. Ali, M.H.; Mawlood, M.K.; Jalal, R.E. Minimizing Energy Losses and Enhancing Performance of Trombe Wall Systems through Partial Evacuation of the Air Gap. Energy Build. 2024, 307, 113959. DOI: https://doi.org/10.1016/j.enbuild.2024.113959
16. Sady, H.; Rashidi, S.; Rafee, R. Towards a Net-Zero-Energy Building with Smart Control of Trombe Walls, Underground Air Ducts, and Optimal Microgrid Composed of Renewable Energy Systems. Energy 2024, 294, 130703. DOI: https://doi.org/10.1016/j.energy.2024.130703
17. Duan, X.; Mi, W.; Guo, S.; Shen, C.; Kalogirou, S.A. Experimental Investigation on a Novel PV-Trombe Wall for Air Heating and Purification in the Severe Cold Region. Renew. Energy 2025, 248, 123126. DOI: https://doi.org/10.1016/j.renene.2025.123126
18. Lashgari, S.; Ardehali, A.; Jahangir, M.H. Comparative Analysis of the Heating Performance of a Hybrid Trombe Wall System with Earth Air Heat Exchanger in a Cold Climate Condition. Results Eng. 2025, 26, 105382. DOI: https://doi.org/10.1016/j.rineng.2025.105382
19. Wu, S.-Y.; Zhao, Y.-M.; Xiao, L. Laboratory Experiment to Study the Effect of Aspect Ratio on Thermal and Purification Performance of Photocatalytic-Trombe Wall. Energy 2025, 332, 137152. DOI: https://doi.org/10.1016/j.energy.2025.137152
20. Kandilli, C.; Gür, M.; Yilmaz, H.; Öztop, H.F. Experimental and Numerical Analyses of a Model Trombe Wall Employing the Natural Zeolite/Perlite Composite Plate as a Thermal Mass for Nearly Zero Energy Buildings. Int. Commun. Heat Mass Transf. 2025, 160, doi:10.1016/j.icheatmasstransfer.2024.108386. DOI: https://doi.org/10.1016/j.icheatmasstransfer.2024.108386
21. Saleem, A.M.; Badr, A.A.; Alyas, B.H.; Alomar, O.R. Performance of Thermal Insulation of Different Composite Walls and Roofs Materials Used for Energy Efficient Building Construction in Iraq. Front. Heat Mass Transf. 2024, 22, 1231–1244, doi:10.32604/fhmt.2024.053770. DOI: https://doi.org/10.32604/fhmt.2024.053770
22. Taylor, G. Potential Use of Wastes of Thermostone Blocks and Ceramic Tiles as Recycled Aggregates in Production of Foam Concrete. Civ. Eng. Archit. 2023.
23. Sharma, S.L.; Kumari, K. Numerical Study of Natural Ventilation in BIPV Trombe Wall. Glob. Res. Dev. J. Eng. 2016, 1, 34–41.
24. Duan, S.; Jing, C.; Zhao, Z. Energy and Exergy Analysis of Different Trombe Walls. Energy Build. 2016, 126, 517–523. DOI: https://doi.org/10.1016/j.enbuild.2016.04.052
25. Dimassi, N.; Dehmani, L. Performance Comparison between an Improved and a Classical Trombe Wall: An Experimental Study. J. Build. Phys. 2017, 40, 372–395, doi:10.1177/1744259116673368. DOI: https://doi.org/10.1177/1744259116673368
26. Briga Sá, A.C.; Martins, A.; Boaventura-Cunha, J.; Carlos Lanzinha, J.; Paiva, A. An Analytical Approach to Assess the Influence of the Massive Wall Material, Thickness and Ventilation System on the Trombe Wall Thermal Performance. J. Build. Phys. 2018, 41, 445–468. DOI: https://doi.org/10.1177/1744259117697389
27. Abbas, E.F. Effect of Air Gap Width on the Evaluation of the Trombe Wall Efficiency. Int. Rev. Mech. Eng. 2019, 13, 655–661, doi:10.15866/ireme.v13i11.17860. DOI: https://doi.org/10.15866/ireme.v13i11.17860
28. Abbas, E.F.; Saleh, R.N. Impact of Absorbent Surface Type on Thermal Performance of Trombe Wall System. Int. J. Innov. Sci. Res. Technol. 2018, 3, 481–485.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2026 Ibrahim Ababakr Ali, Diyar Nadhim Saeed

This work is licensed under a Creative Commons Attribution 4.0 International License.






















Articles in Dasinya Journal for Engineering and Informatics are © their author(s) and published under the